Residential Lighting — A Ready Reckoner for Architects & Designers

  • Jan 15
  • 2 min read

A quick-reference guide for architects, interior designers and homeowners planning residential lighting. Residential light is warm, layered and personal — comfort and mood matter more than raw brightness. Values below are indicative targets for early-stage design; always confirm with a detailed calculation.


Recommended lighting by room

Room

Illuminance (lux)

CCT

CRI

Notes

Living room (ambient)

100–300

2700K

≥90

Layered; dimmable; add reading task at 200–300 lux.

Kitchen (general)

300

3000K

≥90

Counters/task 500 lux, under-cabinet, no shadows on the worktop.

Dining

150–300

2700K

≥90

Pendant over table; dimmable; the social focal point.

Bedroom (ambient)

100–150

2700K

≥90

Bedside/reading 200–300 lux; everything dimmable.

Bathroom + mirror

300–500

2700–3000K

≥90

Vertical light at the face; avoid overhead-only shadows.

Study / home office

500

4000K

≥80

Task-focused, low glare, screen-friendly.

Wardrobe / dressing

300

2700–3000K

≥90

True colour for clothes and skin.

Corridor / stairs

100–150

2700K

≥80

Even, low-glare, safe; night-level option.

Outdoor / facade

low

2700K

≥80

Warm, shielded, glare-controlled; respect neighbours & sky.


Ten principles for residential light

  • Layer every room — ambient + task + accent + decorative. Never rely on one central fitting.

  • 2700K is home. Warm white throughout; keep it consistent within a sightline.

  • Dim everything. A home lives across morning, evening and night — one bright level fits none of them.

  • CRI ≥90 wherever skin, food, art or materials are seen.

  • Put task light where life happens — kitchen counters, reading chairs, the bathroom mirror, the desk.

  • Light the vertical — walls, art and faces — to make rooms feel larger and warmer.

  • Design for the evening. Warm, low, layered light at night is what makes a home feel like one.

  • Add scene / smart control — "welcome", "dinner", "movie", "night" — set once, enjoyed daily.

  • Respect daylight. Orientation changes each room's brief; let electric light respond, not fight it.

  • Keep outdoor warm and shielded — safety and beauty without glare or light pollution.


Specification checklist

  • Layered scheme per room · 2700K default · dimming everywhere

  • CRI ≥90 in living, dining, bath, dressing · task light at kitchen/mirror/desk/reading

  • Glare control · scene/smart control · safe stair & night lighting · warm shielded outdoor


Planning a home? Sketch Lighting designs and manufactures bespoke, custom fixtures for residences across India.

Talk to us — connect@sketchlighting.com · WhatsApp +91 98183 78400.


Indicative values for early-stage design guidance, aligned with common practice and EN 12464-1 principles. Confirm against project brief, local codes and a detailed lighting calculation. © Sketch Lighting.